Checking SWR with a Cross Needle SWR Meter
Checking SWR using a patch cable to connect the SWR meter between the radio and the antenna was discussed earlier. Most of the modern SWR meters are cross needle SWR meters which will show both forward and reflected power with two movements simultaneously along with SWR on another scale. In the SWR meter illustrated here forward power is indicated by the black scale and reflected power by the blue scale. Multiplier for the power can be x1, x10 or x100 depending on the position of the selector which is not shown here. SWR is indicated by the crossing point of the two movements by the red scale.